E. coli

Rodríguez-Chueca et al. 2022 · 279 nm

Bacterium (vegetative) Water 279 nm Gram-negative rod

Test conditions & context

Type Bacterium (vegetative)
Medium Water
Test wavelength 279 nm
Author Rodríguez-Chueca et al.
Year 2022

Umgebungswasser, UV-LED

UV-C dose–response (D-values)

A D-value is the UV-C dose (in mJ/cm²) needed for a given log-reduction. D90 = 90 % inactivation = 1-log; D99 = 99 % = 2-log; D99.9 = 99.9 % = 3-log, and so on. Values come from the cited study under its specific test conditions.

Reduction log Dose (mJ/cm²)
D90 90 % 1-log 1 mJ/cm²
D99 99 % 2-log 2 mJ/cm²
D99.9 99.9 % 3-log 3 mJ/cm²
D99.99 99.99 % 4-log 4 mJ/cm²
D99.999 99.999 % 5-log 5 mJ/cm²
D99.9999 99.9999 % 6-log 6 mJ/cm²

Primary source

Rodríguez-Chueca et al. (2022). pmc.ncbi.nlm.nih.gov/articles/PMC9830170/

Other studies for this species (11)

← UV-C germ database