Staphylococcus aureus

Gayán et al. 2014 · 254 nm

Bacterium (vegetative) Water 254 nm Gram-positive cocci

Test conditions & context

Type Bacterium (vegetative)
Medium Water
Test wavelength 254 nm
Author Gayán et al.
Year 2014

McIlvaine-Puffer, pH 7.0

UV-C dose–response (D-values)

A D-value is the UV-C dose (in mJ/cm²) needed for a given log-reduction. D90 = 90 % inactivation = 1-log; D99 = 99 % = 2-log; D99.9 = 99.9 % = 3-log, and so on. Values come from the cited study under its specific test conditions.

Reduction log Dose (mJ/cm²)
D90 90 % 1-log 6.8 mJ/cm²
D99 99 % 2-log 13.6 mJ/cm²
D99.9 99.9 % 3-log 20.4 mJ/cm²
D99.99 99.99 % 4-log 27.2 mJ/cm²
D99.999 99.999 % 5-log 34 mJ/cm²
D99.9999 99.9999 % 6-log 40.8 mJ/cm²

Primary source

Gayán et al. (2014). pubs.acs.org/doi/10.1021/acs.est.3c08675

Other studies for this species (1)