Adenovirus type 40

Linden et al. 2007 · 254 nm

Virus Water 254 nm Non-enveloped (capsid) virus

Test conditions & context

Type Virus
Medium Water
Test wavelength 254 nm
Author Linden et al.
Year 2007

Polychromatische MP UV-Lampe

UV-C dose–response (D-values)

A D-value is the UV-C dose (in mJ/cm²) needed for a given log-reduction. D90 = 90 % inactivation = 1-log; D99 = 99 % = 2-log; D99.9 = 99.9 % = 3-log, and so on. Values come from the cited study under its specific test conditions.

Reduction log Dose (mJ/cm²)
D90 90 % 1-log 30 mJ/cm²
D99 99 % 2-log 60 mJ/cm²
D99.9 99.9 % 3-log 90 mJ/cm²
D99.99 99.99 % 4-log 120 mJ/cm²
D99.999 99.999 % 5-log 150 mJ/cm²
D99.9999 99.9999 % 6-log 180 mJ/cm²

Morphology & UV-C resistance

Morphology class Non-enveloped (capsid) virus

Nackte Capsid ohne Lipid-Hülle — kompakte ikosaedrische Struktur ist UV-resistent (4× im Vergleich zu hüllbedeckten Viren).

Primary source

Linden et al. (2007). journals.plos.org/plosone/article

← UV-C germ database