Campylobacter jejuni

Moazzami et al. 2021 · 265 nm

Bacterium (vegetative) Surface 265 nm Gram-negative rod

Test conditions & context

Type Bacterium (vegetative)
Medium Surface
Test wavelength 265 nm
Author Moazzami et al.
Year 2021

Transportkistenoberfläche, UV-LED

UV-C dose–response (D-values)

A D-value is the UV-C dose (in mJ/cm²) needed for a given log-reduction. D90 = 90 % inactivation = 1-log; D99 = 99 % = 2-log; D99.9 = 99.9 % = 3-log, and so on. Values come from the cited study under its specific test conditions.

Reduction log Dose (mJ/cm²)
D90 90 % 1-log 6.8 mJ/cm²
D99 99 % 2-log 13.6 mJ/cm²
D99.9 99.9 % 3-log 20.4 mJ/cm²
D99.99 99.99 % 4-log 27.2 mJ/cm²
D99.999 99.999 % 5-log 34 mJ/cm²
D99.9999 99.9999 % 6-log 40.8 mJ/cm²

Primary source

Moazzami et al. (2021). sciencedirect.com/science/article/pii/S2589914724000756