Legionella pneumophila

Oh et al. 2024 · 280 nm

Bacterium (vegetative) Water 280 nm Gram-negative rod

Test conditions & context

Type Bacterium (vegetative)
Medium Water
Test wavelength 280 nm
Author Oh et al.
Year 2024

Gefiltertes Leitungswasser, UV-LED

UV-C dose–response (D-values)

A D-value is the UV-C dose (in mJ/cm²) needed for a given log-reduction. D90 = 90 % inactivation = 1-log; D99 = 99 % = 2-log; D99.9 = 99.9 % = 3-log, and so on. Values come from the cited study under its specific test conditions.

Reduction log Dose (mJ/cm²)
D90 90 % 1-log 6 mJ/cm²
D99 99 % 2-log 12 mJ/cm²
D99.9 99.9 % 3-log 18 mJ/cm²
D99.99 99.99 % 4-log 24 mJ/cm²
D99.999 99.999 % 5-log 30 mJ/cm²
D99.9999 99.9999 % 6-log 36 mJ/cm²

Primary source

Oh et al. (2024). mdpi.com/2073-4441/15/7/1257

Other studies for this species (7)