MS2 Coliphage

Beck et al. 2016 · 260 nm

Virus Water 260 nm Gram-negative rod

Test conditions & context

Type Virus
Medium Water
Test wavelength 260 nm
Author Beck et al.
Year 2016

Abstimmbarer Laser, kollimierter Strahl

UV-C dose–response (D-values)

A D-value is the UV-C dose (in mJ/cm²) needed for a given log-reduction. D90 = 90 % inactivation = 1-log; D99 = 99 % = 2-log; D99.9 = 99.9 % = 3-log, and so on. Values come from the cited study under its specific test conditions.

Reduction log Dose (mJ/cm²)
D90 90 % 1-log 14.3 mJ/cm²
D99 99 % 2-log 28.6 mJ/cm²
D99.9 99.9 % 3-log 42.9 mJ/cm²
D99.99 99.99 % 4-log 57.2 mJ/cm²
D99.999 99.999 % 5-log 71.5 mJ/cm²
D99.9999 99.9999 % 6-log 85.8 mJ/cm²

Primary source

Beck et al. (2016). journals.asm.org/doi/10.1128/AEM.02010-12

Other studies for this species (11)